How to clean a heating system?

Systems should be cleaned when commissioning a new system or installing a new boiler within an existing system. The purpose of cleaning and flushing is to remove mineral oil, harmful flux residues and installation debris which can cause corrosion.

Cleaning existing systems removes magnetite (black iron oxide), haematite (red iron oxide) and limescale improving the circulation and reducing fuel wastage and boiler noise.

New systems domestic 
Fernox Cleaner F3 or Fernox Powerflushing Cleaner F5 should be added before commissioning the system. Simply circulate Fernox Cleaner F3 or Fernox Powerflushing Cleaner F5 for at least one hour when the boiler is switched on, after which the system should be drained and thoroughly flushed until the water runs clear.

Existing systems domestic
Ideally the system should be powerflushed to remove any existing treatment, sludge and contaminant. Fernox Cleaner F3 or Cleaner F5 should be added to system water and circulated hot for at least one hour after which the system must be drained and flushed until the water runs clear. The cleaning time can be extended to up to one week for systems which suffer from hardened iron oxides and limescale.

For both new and existing systems, a Fernox TDS Meter should be used to ensure efficient flushing by comparing the readings of the system water and mains water. The system is thoroughly flushed if the readings are within 10% of each other.  Alternatively, the Fernox Cleaner F3/F5 Test Kit can be used to determine the level of cleaner residues remaining in the system.

Protecting new and existing systems
In accordance with Part L of the Building Regulations, after cleaning with Fernox Cleaner F3 or Fernox Powerflushing Cleaner F5, add Fernox Protector F1 with the final fill water for long-term protection against corrosion and limescale.

All Fernox Protector/Inhibitor products are compatible with commonly used metals in central heating systems, including aluminium, and are suitable for use with plastic pipework. For continued protection, check Protector/Inhibitor levels annually using the Fernox Protector Test Kit or the Fernox System Health Check postal service and top up product level as required.

Share:

More posts:

How to repair system leaks

Leaks in water systems can result from external frost damage, dry solder joints, accidental perforation during maintenance or decoration, or internal corrosion. Sealing internal leaks (central heating systems only) Small leaks, including pressure drops on combination boilers and other sealed systems, can be repaired using Fernox Leak Sealer F4. Each Leak Sealer F4 product treats 100 litres or up to

Read More »

How does it work?

Simply dip the test strip into the system water and it will instantly change colour. By comparing the test strip to the colour chart label on the bottle, installers can assess whether the system water includes the correct concentration of inhibitor. A fully protected system will have inhibitor levels of 100ppm or above – and will pass the test. However,